Customization: | Available |
---|---|
Communication Method: | Lorawan/4G/Nb |
Display Method: | Digital |
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
Type YW-TW intelligent gas meter based on the IoT adopts LoRaWAN/CAT.1/NB wireless transmission technology. Automatically upload gas consumption data to the application platform to realize remote monitoring of gas meter usage status. It solves the problems of the traditional gas meter, such as the difficulty of over-reading the meter at home, the difficulty of paying the fee, and the inaccuracy of the supply and marketing difference.Explosion-proof sign ExibIIBT3 Gb. It is applicable to Zone 1 and Zone 2, containing IIA-IIB and T1-T3 explosive gas mixture.
1. Adopt LoRaWAN/CAT. 1/NB (optional) wireless technology. Effectively increase the anti-interference ability of the communication system and improve the accuracy of the received data;
2. The gas meter adopts the form of system prepayment. The valve switch of the gas meter is realized by the command from the system platform;
3. Timing (once a day) (settable) and key wake-up to transfer data to the platform. It improves the response speed of meter reading and reduces battery energy consumption;
4. When the voltage is low or abnormal, the LCD screen will automatically display the fault information, beep the alarm, and close the valve;
5. It has a built-in antenna. The transmission signal is stable and reliable;
6. The platform can remotely check the user's gas consumption, battery usage, and remotely control the valve switch of the gas meter;
7. It has the function of pulse signal open circuit self-inspection, which can effectively ensure the accuracy of gas meter measurement;
Parameter
|
G(J)1.6
|
Nominal flow(m³ /h)
|
1.6 |
Maximum flow(m³ /h)
|
2.5 |
Minimum flow(m³ /h)
|
0.016 |
Working Pressures(kPa)
|
≤30
|
Total Pressure Loss(Pa)
|
≤250
|
Accuracy Level
|
1.5 Class
|
Basic Error Lines
|
qmin≤q< qt ±3.0% qt≤q≤qmax ±1.5%
|
The tightness of the machine
|
It can last for 3 minutes without leakage under 1.5 times of the maximum working pressure
|
Operating Ambient Temperature(ºC)
|
-25ºC~ +40ºC
|
Inlet and Outlet Connector Threads
|
M30×2
|
Maximum Display Capacity of LCD(m³ )
|
999999 |
Maximum reading of base meter(m³ )
|
99999.999
|
Power supply mode
|
Four AA Alkaline dry batteries(AA LR6 1.5V)
|
LoRaWAN frequency band (MHz)
|
IN864-865
|
Barrier-free meter reading distance
|
>3000m
|
Compliant standards
|
GB/T 6968-2019,GB/T 3836-2021
|
•Consumption: cumulative consumption of gas meter
Parameter |
W(mm)
|
W1(mm)
|
H(mm)
|
CC(mm)
|
L(mm)
|
G1.6 | 152 | 62 | 227 | 130 | 172 |
1. The installation shall be carried out in accordance with GB/T 3836.15-2017 Explosive Atmospheres - Part 15: Design, Selection and Installation of Electrical Installations. The installation of meters shall be carried out by professionals of the gas company for initial installation and commissioning.
2. This product has undergone explosion-proof treatment and shall not be changed at will.
3. The product shall not be collided or severely impacted during transportation, and shall be protected from rain and sand.
4. This product should be stored in a ventilated and dry place.
5. It is prohibited to detect leakage in case of open fire. When piloting fire, the air in the gas meter must be exhausted to prevent accidents.
6. When installing the battery, note that the side with the spring is the negative pole of the battery. The battery shall be replaced under the condition of good ventilation and no gas leakage.
7. Electrostatic hazard, so must be wiped with wrung wet cloth.
1.It is not allowed to replace components or structures that affect the explosion-proof performance at will, so as not to affect the explosion-proof performance.
2.Warning sign: Potential electrostatic charge is dangerous. During the normal use, maintenance and cleaning of gas meters, we should avoid the ignition hazard caused by electrostatic charges. Do not touch and wipe the equipment when it is used in explosive environment. If it is necessary to wipe and touch, it should be carried out in a well-ventilated, no gas leakage place. Wipe the shell with a wrung wet cloth. And it is strictly forbidden to wipe the shell with a dry cloth!
3.The battery must be replaced with the same type of battery under the condition of good ventilation and no gas leakage.
Wuhan TimeWave IOT technology Co., Ltd is a high-tech enterprise specializing in the application of Lora Wide Area Network (LoRaWan) core technology to realize the energy supervision service platform. Providing customers with one-stop overall solutions and services for metering communication equipment, software system platforms, project construction, and daily operation and maintenance management.
Based on the "TimeWave Cloud" energy regulatory platform, covering the measurement, meter reading, charging, management and control of hydropower, gas and heat. It can realize and provide automatic meter reading and charging, carbon emission monitoring, safe electricity consumption, energy consumption analysis, energy saving analysis, distribution and transformation monitoring, power environment monitoring of machine room, intelligent operation and maintenance and other subsystems. And we also independently developed and produced "TimeWave" LPWAN smart meter, intelligent water meter and communication terminal products. We have extensive experience in the practical application of water and electricity meters using Lorawan technology.
The "TimeWave Cloud" energy supervision platform has been widely used in campus, supermarket, apartment, hospital, factory, park, building, railway, airport, computer room and data center. It has been connected to iot Terminal 15W+, Project 200+, radiating 30+ provinces and cities in China, and provides operation and maintenance support for landing projects in Indonesia, Nigeria, Mongolia, Southeast Asia and other countries and regions.
We are committed to solving the problems of difficult meter reading, difficult charging, difficult payment, energy saving and efficiency, and safe energy use for you.